Invensys


Invensys Climate Controls Americas


Company History
News Highlights
Press Releases
Invensys Sites
Job Opportunities
Employee Login








EC4000 SERIES

PROCESS CONTROLS

The EC4000 is a digital electronic 24-hour, single-channel control that manages the same ON/OFF schedule every day, but also allows days to be skipped. Available in NEMA 3R or NEMA 1 to meet the needs of any application, contractors will appreciate this series’ ease of installation.

Download Sell Sheet

Download Manual

You will need Adobe Acrobat Reader to view the manuals. If you do not have this installed, you can download it from Adobe's web site.

FEATURES & BENEFITS

Allows 16 programmable events, with 1-minute minimum ON time per day.
User-friendly control is easy to program with just four keys and a large, easily-read digital display.
Skip-A-Day feature enables users to skip one to seven days.
7-Day Carryover, unique to Paragon, protects scheduled events from power interruptions via a capacitor-more reliable than batteries.
 
UL and CSA listed means quality and durability are built into every time control.
Remote toggle-type override allows immediate reaction to unexpected events without affecting pre-programming or visiting the clock site.
UL and CSA listed means quality and durability are built into every time control.
Title 24 certified.
ENVIRONMENTAL
Operating Temperature Range -40°F to +140°F
Operating Humidity 0-95% non-condensing
Models in NEMA 1 enclosure should be mounted indoors in an environment that is free of excessive contaminants such as oil, moisture and dirt. Models in NEMA 3R non-metallic enclosure are suitable for both indoor and outdoor use.

PHYSICAL
EC4000, EC4004

Enclosure NEMA 1 drawn steel enclosure with lockable hasp. Weight Approximately 2 lbs. (0.9 kg)
Dimensions
  Width 4-1/4” (10.8 cm)
  Height 7-7/8” (20.0 cm)
  Depth 3” (7.6 cm)
Display Size 1-3/4” x 11/16” (7 cm x 1.9 cm)

EC4000PC, EC4004PC & EC4005PC
Enclosure NEMA 3R Non-Metallic with Clear-View cover Weight Approximately 2-1/2 lbs. (1.1 kg)
Dimensions
  Width 6-9/16” (16.7 cm)
  Height 8-1/8” (23.1 cm)
  Depth 3-7/8” (9.8 cm)
Display Size 1-3/4” x 11/16” (7 cm x 1.9 cm)

HOW TO SPECIFY
Installer shall furnish and install Paragon EC4000, EC4004 or EC4005 Electronic Time Control. The single-channel control shall have 24-hour capability with 16 events available. Control shall have keyboard override until overridden again or until next event is reached. Control shall provide 7 days power outage carry-over without a battery. The digital time display shall be 11/16” in height. Clock format shall be selectable, allowing a choice of 12 hour (AM/PM) or 24 hour format. An “ON” or “OFF” display will indicate the current status of the load control contacts. Wiring terminals shall have the capability to accommodate #16 to #10 AWG wire. Control shall be housed in a NEMA 1, lockable steel enclosure or a NEMA 3R lockable enclosure (with Clear-View cover) to guard against vandalism or tampering.

ELECTRICAL SPECIFICATIONS
Model No. Contact
Configuration
Voltage

EC4000/120V SPDT 120 Vac
EC4000PC/120V-RT* SPDT 120 Vac
EC4000PC/120V* SPDT 120 Vac
EC4000/208-277V SPDT 208-277 Vac
EC4000PC/208-277V* SPDT 208-277 Vac
EC4004/120V SPST 120 Vac
EC4004PC/120V* SPST 120 Vac
EC4004PC/120V-RT* SPST 120 Vac
EC4004/208-277V SPST 208-277 Vac
EC4004PC/208-277V* SPST 208-277 Vac
EC4004PC/208-277V-RT* SPST 208-277 Vac
EC4005PC/120, 208-277V-RT* DPST 120/208-240 Vac

*Supplied in a NEMA 3R non-metallic enclosure. PC suffix designates a non-metallic enclosure with Clear-View cover. RT designates retail packaging.

Frequency 50/60 Hz
Power Consumption 4 VA Max.
Wiring Terminals Accommodate #16 to #10 AWG wire
UL Listed, CSA Certified, and comply with FCC rules.
Power Outage Carry-Over
The program and time-of-day are maintained during a power outage for a minimum of 7 days. A built-in, special capacitor eliminates the inconvenience of battery replacement.
Output Switch Ratings
Model EC4000
Normally open contacts:
20 amp resistive (10 amp CSA) at 24-240 Vac
1 Hp (1/2 Hp CSA) at 120 Vac, 2 Hp (1 Hp CSA) at 240 Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac
Model EC4004
Normally open contacts:
30 amp resistive at 24-240 Vac (UL)
30 amp resistive at 120 Vac (CSA)
10 amp resistive at 240 Vac (CSA)
1 Hp at 120 Vac, 2 Hp at 240 Vac
5 amp tungsten at 120-240 Vac
6 amp ballast at 120-277 Vac
Normally closed contacts:
10 amp resistive at 24-240 Vac
1/4 Hp at 120 Vac, 1/2 Hp at 240 Vac
3 amp tungsten at 120-240 Vac
3 amp ballast at 120-277 Vac
Model EC4005PC
Normally open contacts:
30 amp resistive at 120-277 Vac
1 Hp at 120 Vac, 3 Hp at 240 Vac
15 amp tungsten at 120-277 Vac (UL)
5 amp tungsten at 240 Vac (CSA)
20 amp ballast at 120 Vac, 10 amp at 277 Vac

 

 
TYPICAL WIRING DIAGRAMS

DIAGRAM #1 - SPDT

DIAGRAM #2 - SPST

DIAGRAM #3 - DPST

 

Go to top

© Copyright 1999-2004 Invensys Climate Controls. All rights reserved.
Privacy PolicyLegal Information